Dairy Foods
  Home
  Subscribe
  e-newsletter
  Subscription Customer Service
  Online
  Web Exclusives
  Dairy News
  Calendar of Events
  Dairy Field Reports
  DFR Behind the Scenes
  Ask The Experts
  DF Blog
  Videos
  Webinars
  Podcasts
  Source Book
  Supplier Product Guide
  FISA Distributer Guide
  Associations Index
  Current Issue
  Features
  Departments
  New Products + Marketing
  Ingredient Technology
  Plant Operations
  Resources
  Dairy Foods Archives
  Dairy Field Archives
  Digital Edition Archive
  E-Newsletter Archive
  Career Center
  Classified Ads
  Industry Links
  Market Research
  Digital Brochures & Supplements
  Case Studies
  White Papers
  DF Info
  Contact Ad Staff
  Media Kit
  Contact Editorial Staff
  Reprints
  DF Events
  Membrane Short Course
  Special Collections
  Dairy 100
  Supplier Spotlights
Search in: EditorialProductsCompanies
Quality on the Line: Curing “The Monday Morning Blues”
by Henry Randolph
August 1, 2006

ARTICLE TOOLS
EmailEmailPrintPrintReprintsReprintsshareShare

A guide to reducing bacteria counts in dairy products produced following weekend or mid-week “down days”


Higher bacterial counts than normal in products produced after “down days” is not an infrequent occurrence. This condition is often referred to as the “Monday Morning Blues” and is the function of three contributing factors—raw milk quality; cleaning of equipment; and sanitizing of equipment.


Raw milk

It is conceivable that milk processed on Monday morning after a weekend shut down could be as much as five days old before processing begins. This time lapse provides an opportunity for bacterial growth to take place. Raw milk should meet the following minimum standards:
  • No visible butterfat or evidence of churning at time of receiving;
  • Temperature of 40°F or lower;
  • Direct Microscopic Count (DMC)
    • < 100,000 clumps per mL;
  • Standard Plate Count (SPC) – <50,000 colonies per mL; and
  • Preliminary Incubation Count (PI)
    • < 100,000 colonies per mL.


Cleaning of equipment

Care should be taken every day, but especially before a “down day,” to ensure that proper cleaning temperatures, times and concentrations are used. Any residual soils left on equipment surfaces, gaskets, and O-rings will support the growth of bacteria. The multiplication of bacteria is magnified by the extra time and ideal growth temperatures during “down days.” Excessive numbers of bacteria will diminish the effectiveness of the sanitization process. Monitor the CIP system operation and manual cleaning procedures. Do not assume that all functions are operating properly. Dirty equipment cannot be sanitized. Check the following:
  • Be sure that tank outlet valve gaskets fit smoothly between tank face and valve body.
  • Many tank agitators, sample valves, door gaskets and sight glasses must be removed, dismantled and manually cleaned.
  • Gauge down tubes must be cleaned manually or by incorporating them in the CIP of the tank by use of a down tube adapting jumper.
  • Check gauges and manometers for cracks and proper fit.
  • Some pumps in the circuit may need to be completely disassembled and manually cleaned.
  • Non-CIPable HTST vacuum breakers must be dismantled and manually cleaned.
  • Filler valves and assemblies must be cleaned.
  • Jug filler vent tubes must be manually brushed and COP cleaned.


Sanitizing of equipment

All equipment must be sanitized following cleaning and left in a sanitized condition during the “down day.” All line circuits and filler bowls should be flooded with sanitizer and held over the “down day.” Reminder: dirty equipment cannot be sanitized.


Start-Up procedures

The following program/procedures should be considered as a means of “Curing the Monday Morning Blues:”
  • Rewash and resanitize all lines, tank circuits and fillers immediately before production. If rewashing and resanitizing is not possible, follow these steps:

    1. Drain sanitizer from line circuits and fillers.
    2. Sanitize all line circuits, tanks and fillers with recommended CIP sanitizer at ambient temperature. Overflow filler bowls with sanitizer and cycle filler and line valves. Sanitizer must remain in contact with lines and filler surfaces for at least five minutes.
    3. Spray the exterior of the filler bowl, valve assemblies, top breakers and formers, mandrels, transfers, and surrounding area with sanitizer.
    4. Drain sanitizer from milk lines and filler bowls and follow immediately with milk product.
    5. At least once per hour, clear cartons or jugs from the filler and spray the exterior surfaces of the filling equipment and surrounding area with sanitizer. Resume filling.


Application of basic cleaning and sanitizing procedures will cure “The Monday Morning Blues.”



Join Dr. Randolph and Associates for an Advanced Sanitation and Quality Workshop, Nov. 14 – 16, 2006. For registration information, contact Kristy Clark: 205/595-6455 or e-mail kmclark@randolphconsulting.com.


Henry Randolph
HERConsult@aol.com
For more than 40 years, in academic pursuit and as president of Randolph Associates, Inc., Henry Randolph has helped dairy companies find technical and quality solutions to processing concerns.